Flaem Nebulflaem F2000 Nebulizer & Compressor System (3.5 bar)
- Stock: In Stock
- Reward Points: 56
- Model: J028P00
Available Options
Available in the European Union
The average diameter (2.45 μm) of the drug particles in combination with the 3.50 Bar of Maximum Pressure, allows an optimal and quick treatment. As a result the treatment duration is 3-4 minutes per drug. NEBULFLAEM F2000 is suitable for both children and adults, because it spreads across the drug particles in small size, in order that the medication reaches deep into the alveoli of the lungs. Over 80% of the drug particles have a size less than 5 microns (μm).
In the Package: Nebulflaem F2000, one (1) adult silicone mask, one (1) child silicone mask, one (1) connecting tube, one(1) mouthpiece, one (1) nasal tube, one (1) transparent reservoir, a T-shaped safety valve.
Materials and compressor parts are available for 10 years at least
NEBULFLAEM F2000 is a professional, durable and rapid nebulizer compressor system suitable for children and patients with chronic pathologies. NEBULFLAEM F2000 nebulizes the drug particles in such size, so the medication reaches deep into the alveoli. The 80% of drug particles are less than 5 μm and the average particle diameter is about 2.45 μm. Both machine and accessories are made from long-term anti-allergenic materials. It comes with the RapidFlaem 4 nebulizer set .
Treatment Time: ~ 3.5 minutes per treatment
Important Note: For best results and quicker treatments, we recommend to use only one drug per treatment.
TECHNICAL SPECIFICATIONS:
Operating Pressure: ~ 1.1 bar with nebulizer
Maximum Pressure: ~ 3.50 bar
Compressor Air Output: 14 LPM
Size: 20 cm x 27 cm x 10,50 cm (7.87'' x 10.63'' x 4.13'')
Weight: 2.30 kg (5.00 Lbs)
Sound Level (at 1m): 55 dBA
Reservoir's Maximum Capacity: 7 mL, (0.237 ounces), (0.031 cup)
Aerosol Output: 0.65 mL /minute (average values measured with 0.9% saline solution)
Average Particle Diameter: MMAD 2.45 μm (average values measured with 0.9% saline solution)
Non Toxic Materials: Made from non toxic materials
Disinfection: Disinfection by boiling, or when used in clinics or hospitals, autoclave at 121°C (249.80°F) maximum (1.2 bar) for 25 minutes maximum
Operating Requirements: From +10°C to +40°C (+50°F to +104°F)
Relative Humidity for Operation & Storage: ~10-95%
Storage Requirements: From -25°C to +70°C (-13°F to +158°F)
Certified Quality
Manufacturer: Flaem Nuova
Country of Origin: Italy
Part Number: J028P00
ATC Code: Z12159002
Download product brochure